Technical data

Digital laser measure

GLM 50-27 CG

Article number

‎3 601 K72 U..‎

Measuring rangeA)

0.05–50 m

Measuring range (unfavourable conditions)B)

0.05–20 m

Measuring accuracyA)

±1.5 mm

Measuring accuracy (unfavourable conditions)B)

±3.0 mm

Smallest display unit

0.5 mm

General

Operating temperatureC)

–10 °C to +45 °C

Storage temperature

–20 °C to +70 °C

Relative air humidity max.

90 %

Max. altitude

2000 m

Pollution degree according to IEC 61010-1

2D)

Laser class

2

Laser type

515 nm, < 1 mW

Divergence of the laser beam

< 1.5 mrad (full angle)

Automatic switch-off after approx.

  • Laser

20 s

  • Measuring tool (without measurement)E)

5 min

Indirect distance measurement and spirit level

Measuring range

0°–360° (4 × 90°)

Grade measurement

Measuring range

0°–360° (4 × 90°)

Measuring accuracyF)G)

±0.2°

Smallest display unit

0.1°

Weight according to EPTA-Procedure 01:2014

0.17 kg

Protection rating

IP 65 (dust and splash-proof)

Dimensions

119 × 53 × 29 mm

Unit of measurement setting

m, ft, in

Batteries

2 × 1.5 V LR6 (AA)

Battery pack (accessory)

Li-ion

Type

BA 3.7V 1.0Ah A

Article number

‎1 607 A35 17H‎

USB charging connection

Type-C®

Rated voltage

3.7 V

Capacity

1.0 Ah

Number of battery cells

1

Permitted charging temperature range

+10 °C to +35 °C

Power supply

Output voltage

5.0 V

Minimum output current

500 mA

Data transfer

Bluetooth®

Bluetooth® 4.2
(Low Energy)H)

Operating frequency range

2402–2480 MHz

Max. transmission power

8 mW

A)

When measuring from the front edge of the measuring tool, this applies for high reflectivity of the target (e.g. a wall painted white), weak background lighting and a 20 °C operating temperature; a distance-dependent deviation of ±0.05 mm/m must additionally be factored in.

B)

When measuring from the front edge of the measuring tool, this applies for high reflectivity of the target (e.g. a wall painted white), strong background lighting, a 20 °C operating temperature and high elevation; a distance-dependent deviation of ±0.15 mm/m must additionally be factored in.

C)

In continuous measurement mode, the max. operating temperature is +40 °C.

D)

Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.

E)

Bluetooth® deactivated

F)

At an operating temperature of 25 °C

G)

After user calibration at 0° and 90°; An additional grade error of ±0.01°/degree to 45° (max.) has to be taken into account. The left-hand side of the measuring tool serves as the reference level for grade measurement.

H)

When using Bluetooth® Low Energy devices, it may not be possible to establish a connection depending on the model and operating system. Bluetooth® tools must support the GATT profile.

The serial number (11) on the type plate is used to clearly identify your measuring tool.