Starting Operation

Switching On/Off

To switch on the measuring tool, slide the on/off switch (7) to the " On" position (for working with the pendulum lock) or to the " On" position (for working with automatic levelling). The status display (16) lights up. Immediately after switching on, the measuring tool sends a horizontal laser line out of the front outlet aperture (1).

To switch off the measuring tool, slide the on/off switch (7) to the "Off" position. The status indicator (16) goes out. The pendulum unit is locked when the tool is switched off.

If the maximum permitted operating temperature of 45 °C is exceeded, the tool shuts down to protect the laser diode. Once it has cooled down, the measuring tool is operational again and can be switched back on.

Deactivating the automatic shut-off function

The measuring tool automatically switches itself off after 30 min of operation.

To deactivate the automatic shut-off, hold down either the vertical mode button (18) or the horizontal mode button (19) for 3 seconds when switching on the measuring tool. The laser beams will flash briefly after 3 seconds if the automatic shut-off function is deactivated.

To activate the automatic shut-off function, switch the measuring tool off and on again (without holding down a button).